Radio Systems CT-2002 Betriebsanleitung Seite 13

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 12
Radio Systems, Inc. CT-2002 Manual
Page 12
RESETSTOP
START
CLOCK TIMER
CLOCK SET
PROGRAM
1
2
3
4
5
6
78
9
0
MEM 1 MEM 2 MEM 3
MEM 4 MEM 5 MEM 6
Storing Down Times
1. Press the Timer Button.
The Timer Led will illuminate.
2. Using the numeric keypad, enter a down
time. The Set Led and Down Led will illumi-
nate. Hours may be from 00 to 99, minutes
from 00 to 59, and seconds from 00 to 59.
Erroneous entries can be overwritten or the
Reset button can be used to zero the display.
3. Press one of the Store Buttons. If the time
entered was valid, the display will momen-
tarily flash, the Set Led will extinguish and
the down time will be stored. In addition, the
entered down time will remain on the display
and the Down Led will remain illuminated.
However, an invalid time (such as 12:60:00)
will be cleared when a Store Button is
pressed. In addition, the CT-2002 will return
to the Up Timer Mode.
4. Repeat steps 2 and 3 as desired.
Recalling Stored Down Times
1. Press the Timer Button.
The Timer Led will illuminate.
2. Press one of the Store Buttons.
3. The stored down time will appear on the
display. The Down Led will illuminate.
4. Press the Start Button to begin down timing.
5. Press the Stop Button to stop down timing.
6. Press the Start Button to resume down timing.
7. Press the Reset Button once to recall the
selected down time. Repeat steps 3 through 6
as desired.
8. Press the Reset Button two times to exit the
down mode (return to up timing mode) and
clear the display
Note: Stored Down-Time 1 can be recalled
remotely via parallel remote control wiring.
See illustration page 19.
Push to display
Time-of-Day
Push to freeze
Timer Display
When Up-Timing:
Push once to reset timing to 00:00
(Continues to run if reset from Stop)
(Holds if reset from Stop)
When Down-Timing:
Push once to redisplay down time.
Push again to return display to 00:00
and Up-Time mode.
In Clock Mode:
Starts display running from
Time-of-Day set mode
In Timer Mode:
Starts display running from
Up or Down Timer display
Push for Timer Mode
Push to set Time-of-Day
Enter via numeric keypad.
Push start.
Push to set Internal Programming fea-
tures (see setup functions on page 10).
Program functions via
numeric keypad.
Push Timer or Clock to exit
in that mode
To set down time
Enter time via numeric keypad.
Push start to begin.
Push reset to recall downtime.
Push reset 2x to exit.
CT-2002 InfraRed Remote Control
MEM 6 is retasked to switch the
timer between slave and local
modes when using associated dis-
play as a remote timer. See page 7.
Seitenansicht 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 27 28

Kommentare zu diesen Handbüchern

Keine Kommentare